| Item | DDV-01GP | DDV-25GP |
| Messurable range of dynamic modules of elasticity | 0.05 ~ 1.6 x 105 Mpa (5 x 105~ 1.6 x 1012 dyne/cm2) |
0.05 ~ 5 x 105 Mpa (5 x 105~ 1.6 x 1012 dyne/cm2) |
| Measurable range of tan δ | ±0.001 ~ ±9.999 (resolution 0.0001) | ±0.001 ~±9.999 (resolution 0.0001) |
| Measuring frequency | 0.01 ~ 110Hz (137points) | 0.01 ~ 110Hz (137points) |
| Dynamic vibration range | ±4 ~±160µm | ±8 ~±250µm (±500µm optional) |
| Measuring range o dynamic load | ±3 x 10-4~ 1N (approx. ±0.03gf ~±100gf) | ±0.01 ~±25N (approx. 1gf ~±2500gf) |
| Testpiece size | 10 ~ 60 mm(L), 1~4mm(W), 0.005~0.5mm(T) | 10 ~ 70 mm(L), 1~10mm(W), 0.1~5mm(T) |
| Test jig | Elongation, shearing (for solid), DSA method |
Elongation, compression, bending, shearing (for solid), DSA method |
| High/low temperature ture chamber | -150°C ~ +400°C ±2°C at -150°C, ±4°C at +400°C Isochronous temprature rise, Step temperature rise, Constant temperature 0.5 ~ 10°C/min (upto 300°C) 0.5 ~ 9°C/min (upto 400°C) step width more than 10°C |
-150°C ~ +400°C ±2°C at -150°C, ±4°C at +250°C, ±6°C at +400°C Isochronous temprature rise, Step temperature rise, Constant temperature 0.5 ~ 10°C/min (upto 300°C) 0.5 ~ 9°C/min (upto 400°C) step width more than 10°C |
| Data process | Personal computer Temperature dispersion behavior test Strain dispersion test Age-based behavior test |
Personal computer Temperature dispersion behavior test Strain dispersion test Age-based behavior test |
| Power supply | 100V AC ± 10% 1o 50/60Hz approx. 1300VA | 100V AC ± 10% 1o 50/60Hz approx. 1800VA Air Compression 400kPa approx. 35 lit/min |
| Dimension and weight | Measurement operating block & high/low temperature chamber 620 (Width) x 620 (Height) x 590 (Depth) mm approx. 150kg |
Measurement operating block & high/low temperature chamber 720 (Width) x 620 (Height) x 590 (Depth) mm approx. 200kg |
Both models require MSAT for data processing.

MSAT (Multi Signal Analysis Testing)
Data processing software
The MSAT series is equipped with functions for not only testing machine operation but also data analysis, calculation and data storage for each testing mode. The operator can select curbing behaviors or physical properties depending on the purpose of the test.
PC operation environment OS: Windows XP Professional. Program size: 80Mb or smaller. Memory requirement: 512Mb or over. Authority requirement: Administrator authority. USB: One USB port. Display resolution: 800×600 dots or higher color display.
Highlights
Features
| Item | DDV-01GP | DDV-25GP |
| Messurable range of dynamic modules of elasticity | 0.05 ~ 1.6 x 105 Mpa (5 x 105~ 1.6 x 1012 dyne/cm2) |
0.05 ~ 5 x 105 Mpa (5 x 105~ 1.6 x 1012 dyne/cm2) |
| Measurable range of tan δ | ±0.001 ~ ±9.999 (resolution 0.0001) | ±0.001 ~±9.999 (resolution 0.0001) |
| Measuring frequency | 0.01 ~ 110Hz (137points) | 0.01 ~ 110Hz (137points) |
| Dynamic vibration range | ±4 ~±160µm | ±8 ~±250µm (±500µm optional) |
| Measuring range o dynamic load | ±3 x 10-4~ 1N (approx. ±0.03gf ~±100gf) | ±0.01 ~±25N (approx. 1gf ~±2500gf) |
| Testpiece size | 10 ~ 60 mm(L), 1~4mm(W), 0.005~0.5mm(T) | 10 ~ 70 mm(L), 1~10mm(W), 0.1~5mm(T) |
| Test jig | Elongation, shearing (for solid), DSA method |
Elongation, compression, bending, shearing (for solid), DSA method |
| High/low temperature ture chamber | -150°C ~ +400°C ±2°C at -150°C, ±4°C at +400°C Isochronous temprature rise, Step temperature rise, Constant temperature 0.5 ~ 10°C/min (upto 300°C) 0.5 ~ 9°C/min (upto 400°C) step width more than 10°C |
-150°C ~ +400°C ±2°C at -150°C, ±4°C at +250°C, ±6°C at +400°C Isochronous temprature rise, Step temperature rise, Constant temperature 0.5 ~ 10°C/min (upto 300°C) 0.5 ~ 9°C/min (upto 400°C) step width more than 10°C |
| Data process | Personal computer Temperature dispersion behavior test Strain dispersion test Age-based behavior test |
Personal computer Temperature dispersion behavior test Strain dispersion test Age-based behavior test |
| Power supply | 100V AC ± 10% 1o 50/60Hz approx. 1300VA | 100V AC ± 10% 1o 50/60Hz approx. 1800VA Air Compression 400kPa approx. 35 lit/min |
| Dimension and weight | Measurement operating block & high/low temperature chamber 620 (Width) x 620 (Height) x 590 (Depth) mm approx. 150kg |
Measurement operating block & high/low temperature chamber 720 (Width) x 620 (Height) x 590 (Depth) mm approx. 200kg |
Both models require MSAT for data processing.

MSAT (Multi Signal Analysis Testing)
Data processing software
The MSAT series is equipped with functions for not only testing machine operation but also data analysis, calculation and data storage for each testing mode. The operator can select curbing behaviors or physical properties depending on the purpose of the test.
PC operation environment OS: Windows XP Professional. Program size: 80Mb or smaller. Memory requirement: 512Mb or over. Authority requirement: Administrator authority. USB: One USB port. Display resolution: 800×600 dots or higher color display.