Shop
AD-4212D Series Weigh Modules
High Readability, High Stability, Space-Saving And Cost-Saving
Highlights
Features
Downloads
Highlights
- Readability from 1 µg
- EM-DLC* technology for direct connection to a PC or PLC
- Compact size and resistance to vacuum state ideal for use in a glove box
- Stable measurement in a fume hood**
- Internal calibration function to ensure accuracy with one key press
- Protection mechanism against vertical and transverse overloading due to actuator malfunctions, etc.
- Adjustable response characteristics to help cope with the effects of drafts and vibrations
- Automatic zero display after data output
- Equipped with a small breeze break
- Possible to design and attach your preferred weighing pan/receptacle
- Clock and calendar function
- Underhook for weighing magnetic materials and density measurements
- GMP/GCP/ISO compliant output
- Clock and calendar function
- Built-in temperature sensor for temperature data output
- Can be secured directly to a base by removing the leveling feet and using screws
- Water-resistant cap for cleaning***
- High extensibility with A&D’s various peripheral devices
- AD-1691 weighing environment analyzer provided as standard* Electromagnetic Digital Load Cell
** For 0.1 mg readability. Stable measurement at 0.01 mg readability will also be possible when used with the AD-1675 tabletop breeze break.
*** The AD-4212D has an IP65 rating when the cap is put on the pan support boss (after removing the weighing pan and pan support).
Features
| Model | AD-4212D-33 | AD-4212D-32 | AD-4212D-302 | AD-4212D-301 |
| Capacity | 32 g | 5.1 g / 32 g*1 | 320 g | 320 g |
| Readability | 0.001 mg | 0.001 mg / 0.01 mg*1 | 0.01 mg | 0.1 mg |
| Stabilization time (when set to FAST under a good environment) | Approx. 7 sec | Approx. 7 sec | Approx. 7 sec | Approx. 3 sec |
| Repeatability (Standard deviation) |
0.002 mg*2 | 0.004 mg*2 / 0.02 mg | 0.02 mg*3 | 0.07 mg*3 |
| Linearity | ±0.02 mg | ±0.03 mg | ±0.15 mg | ±0.25 mg |
| Sensitivity drift (10 °C to 30 °C) | ±2 ppm/ °C | |||
| Weighing pan | Ø34 mm | Ø50 mm | ||
*1 Smart range function: The display will switch to the standard range automatically when the value exceeds 5.1 g but return to the precision range when RE-ZERO (tare) is performed.
*2 Repeatability for a 1 g mass using an automatic loading machine
*3 For a 10 g mass over the entire range
Downloads
Highlights
- Readability from 1 µg
- EM-DLC* technology for direct connection to a PC or PLC
- Compact size and resistance to vacuum state ideal for use in a glove box
- Stable measurement in a fume hood**
- Internal calibration function to ensure accuracy with one key press
- Protection mechanism against vertical and transverse overloading due to actuator malfunctions, etc.
- Adjustable response characteristics to help cope with the effects of drafts and vibrations
- Automatic zero display after data output
- Equipped with a small breeze break
- Possible to design and attach your preferred weighing pan/receptacle
- Clock and calendar function
- Underhook for weighing magnetic materials and density measurements
- GMP/GCP/ISO compliant output
- Clock and calendar function
- Built-in temperature sensor for temperature data output
- Can be secured directly to a base by removing the leveling feet and using screws
- Water-resistant cap for cleaning***
- High extensibility with A&D’s various peripheral devices
- AD-1691 weighing environment analyzer provided as standard* Electromagnetic Digital Load Cell
** For 0.1 mg readability. Stable measurement at 0.01 mg readability will also be possible when used with the AD-1675 tabletop breeze break.
*** The AD-4212D has an IP65 rating when the cap is put on the pan support boss (after removing the weighing pan and pan support).
Features
| Model | AD-4212D-33 | AD-4212D-32 | AD-4212D-302 | AD-4212D-301 |
| Capacity | 32 g | 5.1 g / 32 g*1 | 320 g | 320 g |
| Readability | 0.001 mg | 0.001 mg / 0.01 mg*1 | 0.01 mg | 0.1 mg |
| Stabilization time (when set to FAST under a good environment) | Approx. 7 sec | Approx. 7 sec | Approx. 7 sec | Approx. 3 sec |
| Repeatability (Standard deviation) |
0.002 mg*2 | 0.004 mg*2 / 0.02 mg | 0.02 mg*3 | 0.07 mg*3 |
| Linearity | ±0.02 mg | ±0.03 mg | ±0.15 mg | ±0.25 mg |
| Sensitivity drift (10 °C to 30 °C) | ±2 ppm/ °C | |||
| Weighing pan | Ø34 mm | Ø50 mm | ||
*1 Smart range function: The display will switch to the standard range automatically when the value exceeds 5.1 g but return to the precision range when RE-ZERO (tare) is performed.
*2 Repeatability for a 1 g mass using an automatic loading machine
*3 For a 10 g mass over the entire range