• 0Shopping Cart
A&D Instruments Thailand Limited
  • Home
  • Products
    • Weighing
      • Balances
      • Scales
      • Indicators
      • Load Cells
    • Inspection Systems
      • Checkweighers
      • Metal Detectors
      • X-ray Inspection Systems
    • Test and Measurement
      • Universal Testing Instruments
      • Moisture Analyzers
      • Data Acquisition
      • Viscometers / Rheometers
      • Noise & Vibration Analysis
      • Material Testing Instruments
    • Medical
      • Professional Lines
      • Medical Scales
      • Personal Lines
      • Telemedicine
  • Company
    • About Us
    • Message
    • Company Profile
    • Leadership
    • History
    • Global Coverage
  • Support
    • Contact Us
    • Help & FAQ
    • Information Library
  • Search
  • Menu Menu
Shop
You are here: Home1 / Industries2 / Construction3 / A&D Apollo GX-AE/A & GF-A Series Advanced-Level Analytical/Precision...
A&D Apollo GX-AE/A & GF-A Series Advanced-Level Analytical/Precision Balances
A&D Apollo GX-AE/A & GF-A Series Advanced-Level Analytical/Precision Balances - Image 2
A&D Apollo GX-AE/A & GF-A Series Advanced-Level Analytical/Precision Balances - Image 3
A&D Apollo GX-AE/A & GF-A Series Advanced-Level Analytical/Precision Balances - Image 4
A&D Apollo GX-AE/A & GF-A Series Advanced-Level Analytical/Precision Balances - Image 5
A&D Apollo GX-AE/A & GF-A Series Advanced-Level Analytical/Precision Balances - Image 6
A&D Apollo GX-AE/A & GF-A Series Advanced-Level Analytical/Precision Balances - Image 7
A&D Apollo GX-AE/A & GF-A Series Advanced-Level Analytical/Precision Balances - Image 8
A&D Apollo GX-AE/A & GF-A Series Advanced-Level Analytical/Precision Balances - Image 9

A&D Apollo GX-AE/A & GF-A Series Advanced-Level Analytical/Precision Balances

Taking Weighing Precision and Protection to New Heights


Enquiry
Help & FAQ





Highlights
Features
Downloads
Highlights
  • Impact shock detection (ISD) providing feedback to prevent damage to the weight sensor*1
  • Electronically controlled load (ECL) that enables precision management without using an external weight*1
  • Flow rate display (FRD) that makes calculating and recording flow rates easier and more accurate*2
  • Smart super hybrid sensor (Smart SHS) that realizes fast stabilization, long-term durability and low cost of ownership
  • Shock logging function that records up to 50 adverse impact loads with a timestamp for later inspection
  • Cushioning under the weighing pan to mitigate impact shocks significantly
  • Protection against vertical and transverse static overloading
  • Flow rate comparator that indicates whether the flow rate is within the designated limits
  • Tare memory function that saves the tare value in non-volatile memory
  • Built-in fanless ionizer with Quick Ion® technology and external IR switch (GX-AE)
  • Large and detachable, antistatic glass breeze break (0.0001 g readability models)
  • Retractable doors that disappear into the back, requiring no extra space at the rear
  • Automatic self calibration in response to temperature changes or according to set schedules (GX-AE/A)
  • Automatic minimum weight calculation with either ECL or an actual, external weight
  • Alert function to ensure that the measured quantity is not smaller than the set minimum weight
  • Selectable response characteristics for trading weighing speed for higher display stability or vice versa
  • Large, front-mounted spirit level with LED illumination
  • Easy-to-adjust leveling feet with thumbwheels
  • User access control (UAC) that password-protects the balance from misusage
  • GLP/GMP/GCP/ISO compliant output to meet documentation requirements
  • Universal Flexi Coms (UFC) to customize printout content and layout*3
  • Gross/Net/Tare output
  • Data memory function to save weighing results, calibration results and unit masses to be used in counting mode in the device itself
  • Counting mode with the Automatic Counting Accuracy Improvement (ACAI) function
  • Percent mode function for target weighing or checking sample variation
  • Animal weighing (average & hold) function for weighing moving objects
  • Statistical calculation function (SCF) to facilitate the analysis of measurements
  • Five-level comparator function with buzzer
  • Auto power ON and OFF functions
  • Density determination function (optional density determination kits available for the 0.0001/0.001 g readability models)
  • Underhook for weighing a magnetic material as well as measuring density

*1 Patented
*2 For graphing weight and flow rate changes in real time, download WinCT-FRD here
*3 For editing and sending UFC setting commands, download WinCT-UFC here

Features
Models GX-124AE
GX-124A
GF-124A
GX-224AE
GX-224A
GF-224A
GX-324AE
GX-324A
GF-324A
Capacity 122 g 220 g 320 g
Readability 0.0001 g
Repeatability (standard deviation) 0.0001 g 0.0002 g (300 g)
0.0001 g (200 g)
Minimum weight* (typical) 120 mg
Linearity ±0.0002 g ±0.0003 g
Stabilization time (when set to FAST under a good environment) Approx. 1.5 sec (100 g) Approx. 2 sec (200 g)
Approx. 1.5 sec (100 g)
Approx. 2 sec (300 g)
Approx. 1.5 sec (100 g)
Weighing pan size Ø90 mm
External dimensions 259 (W) × 358 (D) × 332 (H) mm (including the large glass breeze break)
Net weight Approx. 7 kg
Models GF-123A GX-203A
GF-203A
GX-303A
GF-303A
GX-403A
GF-403A
GX-603A
GF-603A
GX-1003A
GF-1003A
GX-1603A
GF-1603A
Capacity 122 g 220 g 320 g 420 g 620 g 1100 g 1620 g
Readability 0.001 g
Repeatability (standard deviation) 0.001 g 0.002 g (1600 g)
0.001 g (1000 g)
Minimum weight* (typical) 1.4 g
Linearity ±0.002 g ±0.003 g
Stabilization time (when set to FAST under a good environment) Approx. 1 sec
Approx. 0.8 sec (5 g)
Approx. 1.5 sec
Approx. 0.8 sec (5 g)
Weighing pan size 128 mm × 128 mm
External dimensions 212 (W) × 317 (D) × 171 (H) mm (including the small plastic breeze break)
Net weight Approx. 5 kg
Models GF-1202A GX-2002A
GF-2002A
GX-3002A
GF-3002A
GX-4002A
GF-4002A
GX-6002A
GF-6002A
GX-10002A
GF-10002A
GX-6001A
GF-6001A
GX-10001A
GF-10001A
Capacity 1220 g 2200 g 3200 g 4200 g 6200 g 10200 g 6200 g 10200 g
Readability 0.01 g 0.1 g
Repeatability (standard deviation) 0.01 g 0.02 g (10000 g)
0.01 g (5000 g)
0.1 g
Minimum weight* (typical) 14 g 100 g
Linearity ±0.02 g ±0.03 g ±0.1 g
Stabilization time (when set to FAST under a good environment) Approx. 1 sec
Approx. 0.8 sec (50 g)
Approx. 1.5 sec
Approx. 0.8 sec (50 g)
Approx. 1 sec
Approx. 0.8 sec (500 g)
Weighing pan size 165 mm × 165 mm
External dimensions 212 (W) × 317 (D) × 93 (H) mm
Net weight Approx. 5 kg

* Pursuant to the United States Pharmacopeia (USP), Chapter 41

Downloads
Brochure
Manual
Manual - FRD Addendum
Supplementary manual for the GF-123/1202A
Communication manual
ECL and the USP Minimum Weight Standard
GXA-03 / GXA-04 / GXA-06 Manual
FXi-08 Manual
GXA-09 Manual
GXA-10 Manual
GXA-12 Manual
GXA-13 Manual
GXA-14 Manual
GXA-17 Manual
GXA-23 / GXA-26 Manual
GXA-24 Manual
GXA-25 Manual
Virtual COM mode driver software for the GX-A/GF-A series USB interface

Highlights

  • Impact shock detection (ISD) providing feedback to prevent damage to the weight sensor*1
  • Electronically controlled load (ECL) that enables precision management without using an external weight*1
  • Flow rate display (FRD) that makes calculating and recording flow rates easier and more accurate*2
  • Smart super hybrid sensor (Smart SHS) that realizes fast stabilization, long-term durability and low cost of ownership
  • Shock logging function that records up to 50 adverse impact loads with a timestamp for later inspection
  • Cushioning under the weighing pan to mitigate impact shocks significantly
  • Protection against vertical and transverse static overloading
  • Flow rate comparator that indicates whether the flow rate is within the designated limits
  • Tare memory function that saves the tare value in non-volatile memory
  • Built-in fanless ionizer with Quick Ion® technology and external IR switch (GX-AE)
  • Large and detachable, antistatic glass breeze break (0.0001 g readability models)
  • Retractable doors that disappear into the back, requiring no extra space at the rear
  • Automatic self calibration in response to temperature changes or according to set schedules (GX-AE/A)
  • Automatic minimum weight calculation with either ECL or an actual, external weight
  • Alert function to ensure that the measured quantity is not smaller than the set minimum weight
  • Selectable response characteristics for trading weighing speed for higher display stability or vice versa
  • Large, front-mounted spirit level with LED illumination
  • Easy-to-adjust leveling feet with thumbwheels
  • User access control (UAC) that password-protects the balance from misusage
  • GLP/GMP/GCP/ISO compliant output to meet documentation requirements
  • Universal Flexi Coms (UFC) to customize printout content and layout*3
  • Gross/Net/Tare output
  • Data memory function to save weighing results, calibration results and unit masses to be used in counting mode in the device itself
  • Counting mode with the Automatic Counting Accuracy Improvement (ACAI) function
  • Percent mode function for target weighing or checking sample variation
  • Animal weighing (average & hold) function for weighing moving objects
  • Statistical calculation function (SCF) to facilitate the analysis of measurements
  • Five-level comparator function with buzzer
  • Auto power ON and OFF functions
  • Density determination function (optional density determination kits available for the 0.0001/0.001 g readability models)
  • Underhook for weighing a magnetic material as well as measuring density

*1 Patented
*2 For graphing weight and flow rate changes in real time, download WinCT-FRD here
*3 For editing and sending UFC setting commands, download WinCT-UFC here

Features

Models GX-124AE
GX-124A
GF-124A
GX-224AE
GX-224A
GF-224A
GX-324AE
GX-324A
GF-324A
Capacity 122 g 220 g 320 g
Readability 0.0001 g
Repeatability (standard deviation) 0.0001 g 0.0002 g (300 g)
0.0001 g (200 g)
Minimum weight* (typical) 120 mg
Linearity ±0.0002 g ±0.0003 g
Stabilization time (when set to FAST under a good environment) Approx. 1.5 sec (100 g) Approx. 2 sec (200 g)
Approx. 1.5 sec (100 g)
Approx. 2 sec (300 g)
Approx. 1.5 sec (100 g)
Weighing pan size Ø90 mm
External dimensions 259 (W) × 358 (D) × 332 (H) mm (including the large glass breeze break)
Net weight Approx. 7 kg
Models GF-123A GX-203A
GF-203A
GX-303A
GF-303A
GX-403A
GF-403A
GX-603A
GF-603A
GX-1003A
GF-1003A
GX-1603A
GF-1603A
Capacity 122 g 220 g 320 g 420 g 620 g 1100 g 1620 g
Readability 0.001 g
Repeatability (standard deviation) 0.001 g 0.002 g (1600 g)
0.001 g (1000 g)
Minimum weight* (typical) 1.4 g
Linearity ±0.002 g ±0.003 g
Stabilization time (when set to FAST under a good environment) Approx. 1 sec
Approx. 0.8 sec (5 g)
Approx. 1.5 sec
Approx. 0.8 sec (5 g)
Weighing pan size 128 mm × 128 mm
External dimensions 212 (W) × 317 (D) × 171 (H) mm (including the small plastic breeze break)
Net weight Approx. 5 kg
Models GF-1202A GX-2002A
GF-2002A
GX-3002A
GF-3002A
GX-4002A
GF-4002A
GX-6002A
GF-6002A
GX-10002A
GF-10002A
GX-6001A
GF-6001A
GX-10001A
GF-10001A
Capacity 1220 g 2200 g 3200 g 4200 g 6200 g 10200 g 6200 g 10200 g
Readability 0.01 g 0.1 g
Repeatability (standard deviation) 0.01 g 0.02 g (10000 g)
0.01 g (5000 g)
0.1 g
Minimum weight* (typical) 14 g 100 g
Linearity ±0.02 g ±0.03 g ±0.1 g
Stabilization time (when set to FAST under a good environment) Approx. 1 sec
Approx. 0.8 sec (50 g)
Approx. 1.5 sec
Approx. 0.8 sec (50 g)
Approx. 1 sec
Approx. 0.8 sec (500 g)
Weighing pan size 165 mm × 165 mm
External dimensions 212 (W) × 317 (D) × 93 (H) mm
Net weight Approx. 5 kg

* Pursuant to the United States Pharmacopeia (USP), Chapter 41

Downloads

Brochure
Manual
Manual - FRD Addendum
Supplementary manual for the GF-123/1202A
Communication manual
ECL and the USP Minimum Weight Standard
GXA-03 / GXA-04 / GXA-06 Manual
FXi-08 Manual
GXA-09 Manual
GXA-10 Manual
GXA-12 Manual
GXA-13 Manual
GXA-14 Manual
GXA-17 Manual
GXA-23 / GXA-26 Manual
GXA-24 Manual
GXA-25 Manual
Virtual COM mode driver software for the GX-A/GF-A series USB interface


UC-351PBT-Ci Precision Health ScaleAPOLLO GX-AE/A & GF-A Series (Copy)
Scroll to top