• 0Shopping Cart
A&D Instruments Thailand Limited
  • Home
  • Products
    • Weighing
      • Balances
      • Scales
      • Indicators
      • Load Cells
    • Inspection Systems
      • Checkweighers
      • Metal Detectors
      • X-ray Inspection Systems
    • Test and Measurement
      • Universal Testing Instruments
      • Moisture Analyzers
      • Data Acquisition
      • Viscometers / Rheometers
      • Noise & Vibration Analysis
      • Material Testing Instruments
    • Medical
      • Professional Lines
      • Medical Scales
      • Personal Lines
      • Telemedicine
  • Company
    • About Us
    • Message
    • Company Profile
    • Leadership
    • History
    • Global Coverage
  • Support
    • Contact Us
    • Help & FAQ
    • Information Library
  • Search
  • Menu Menu
Shop
You are here: Home1 / Weighing2 / Balances3 / AD-8922A Remote Controller
AD-8922A Remote Controller

AD-8922A Remote Controller

The AD-8922A is a remote controller that can be connected to an A&D manufactured weighing instrument using the RS-232C serial interface.


Enquiry
Help & FAQ





Highlights
Features
Downloads
Highlights
  • Displays weighing data
  • Remotely controls a weighing instrument with key operations (no access to the internal settings)
  • Outputs weighing data to another external device such as a PC or printer via the RS-232C connection
  • Optional BCD, comparator, and analog outputs available
  • Can be panel-mounted
Features
Power supply AC adapter
Power consumption Approx. 11 VA including the AC adapter (Approx. 1.5 VA for the AD-8922A)
Standard interface RS-232C
Baud rate 600, 1200, 2400, 4800, 9600, 19200 bps
Refresh rate Approx. 10 times/second (when the baud rate is 2400 bps or greater).
Applicable connectors D-Sub 9-pin (Male) to connect to the weighing instrument
DIN 8-pin (Female) to connect to an external device
Dimensions 238 (W) × 132 (D) × 170 (H) mm
Net weight Approx. 1.0 kg
Standard accessories AC adapter, communications cable (Approx. 2 m)
Weighing instrument AD-8922 Key
ON:OFF CAL SAMPLE PRINT MODE RE-ZERO
AD-4212C Turns the
weighing
instrument
display
on or off. *1
Calibrates
using the
external mass.
Switches
the
minimum
display. *2
Outputs
the
received
data to
an
external
device. *3
Switches
the response characteristic.
Sets the
display to zero.
GX, GX-K, GP,
GH, ET-W, FZ-i
Calibrates
using the
internal mass.
Switches
the unit
displayed. *4
GR
GF, GF-K,
EK-H,
AD-4212A/B, HR,HR-i, FX-i
–
EK-i,EW-i – – –
EK-G, EW-G, FC-i,FC-Si,
FG, FG-L,FG-M, FP, FS,
FS-KL,HV-G, HV-WP,
HW-G,HW-WP
– – – – –

Note: “-” in the table indicates that the key operation is not available.
*1: Switches between standby and weighing mode on the AD-4212C.
*2: Not applicable to the counting mode and the percent mode. Switching the minimum display is not available for the ET-W.
*3: Available when the AD-8922A is in key mode (“out 1” or “out 2” of the function setting).
*4: Not available for the ET-W and AD-4212

Downloads
Manual

Highlights

  • Displays weighing data
  • Remotely controls a weighing instrument with key operations (no access to the internal settings)
  • Outputs weighing data to another external device such as a PC or printer via the RS-232C connection
  • Optional BCD, comparator, and analog outputs available
  • Can be panel-mounted

Features

Power supply AC adapter
Power consumption Approx. 11 VA including the AC adapter (Approx. 1.5 VA for the AD-8922A)
Standard interface RS-232C
Baud rate 600, 1200, 2400, 4800, 9600, 19200 bps
Refresh rate Approx. 10 times/second (when the baud rate is 2400 bps or greater).
Applicable connectors D-Sub 9-pin (Male) to connect to the weighing instrument
DIN 8-pin (Female) to connect to an external device
Dimensions 238 (W) × 132 (D) × 170 (H) mm
Net weight Approx. 1.0 kg
Standard accessories AC adapter, communications cable (Approx. 2 m)
Weighing instrument AD-8922 Key
ON:OFF CAL SAMPLE PRINT MODE RE-ZERO
AD-4212C Turns the
weighing
instrument
display
on or off. *1
Calibrates
using the
external mass.
Switches
the
minimum
display. *2
Outputs
the
received
data to
an
external
device. *3
Switches
the response characteristic.
Sets the
display to zero.
GX, GX-K, GP,
GH, ET-W, FZ-i
Calibrates
using the
internal mass.
Switches
the unit
displayed. *4
GR
GF, GF-K,
EK-H,
AD-4212A/B, HR,HR-i, FX-i
–
EK-i,EW-i – – –
EK-G, EW-G, FC-i,FC-Si,
FG, FG-L,FG-M, FP, FS,
FS-KL,HV-G, HV-WP,
HW-G,HW-WP
– – – – –

Note: “-” in the table indicates that the key operation is not available.
*1: Switches between standby and weighing mode on the AD-4212C.
*2: Not applicable to the counting mode and the percent mode. Switching the minimum display is not available for the ET-W.
*3: Available when the AD-8922A is in key mode (“out 1” or “out 2” of the function setting).
*4: Not available for the ET-W and AD-4212

Downloads

Manual


AD-8920A Remote DisplayAD-8527 Quick USB Adaptor
Scroll to top