Shop
TM-2430 Ambulatory Blood Pressure Monitor
The TM-2430 is a compact & lightweight ambulatory blood pressure monitor, which incorporates our latest technology gained from over 20 years experience in the manufacturing of ambulatory BPMs. This monitor was validated in accordance with BHS protocol and its accuracy was proven to be A/A. Weighing only 215 grams, and the size of a cigarette pack, the portable TM-2430 can be easily taken anywhere with a patient.
Highlights
Features
Downloads
Highlights
- 24 hour ambulatory blood pressure monitoring
- Light weight & compact size – only 156 grams
- Oscillometric measuring method
- Automatically adjusts: Proper Cuff Pressure, Exhaust, End of Measurement
- New pulse correction algorithm for faster measurement & noise rejection
- Automatic or manual measurement
- Battery Power (3 alkaline or Ni-Cd “AA”)
- Date/Time display: 1997-2096 & auto leap year
- Multiple measurement intervals – adapts to patient’s exact requirements
- Data output to computer or printer
- RS-232C Connectivity
Features
| BP Measurement | |
| Measurement Method | Oscillometric |
| Measuring Range | |
| Blood Pressure | 40 ~ 280 mmHg (SYS – 60 ~ 280mmHg/DIA – 40 ~ 160mmHg) |
| Pulse | 30 ~ 200 bpm |
| Accuracy | |
| Blood Pressure | +/- 3 mmHg |
| Pulse | +/-5% |
| Pressurization | |
| Method | Micro pump |
| Maximum Pressure | 300 mmHg |
| Preset Pressure | Automatic |
| Depressurization | |
| Method | Electric Controlled Exhaust Valve (ECEV) |
| Safety System | A magnetic, solenoid valve opens when the pressure exceeds approximately 320 mmHg. Over 330 mmHg, an independent safety circuit exhausts air. |
| Interval Setting | 5, 10, 15, 20, 30, 60, 120 min. |
| Clock | 24 hour clock, calendar (~ year 2096) |
| Memory Data | Up to 300 sets of data |
| Power Supply | |
| Battery | 3x LR6 (“AA”) type batteries – alkaline or Ni-cd type |
| Battery Life | Approx. 200 measurements |
| Temperature & Humidity | |
| Operating Temperatures | 10°C ~ 40°C (50°F ~ 104°F), Less than 85%RH (non-condensing) |
| Storage & Transportation | -20°C ~ 55°C (14°F ~ 131°F), Less than 95%RH (non-condensing) |
| External Dimensions | 72(W) x 27(H) x 100(D) mm/2.8(W) x 1.0(H) x 3.9(D) inches |
| Weight | Approx. 215g (0.47lb) without cuff |
Downloads
Highlights
- 24 hour ambulatory blood pressure monitoring
- Light weight & compact size – only 156 grams
- Oscillometric measuring method
- Automatically adjusts: Proper Cuff Pressure, Exhaust, End of Measurement
- New pulse correction algorithm for faster measurement & noise rejection
- Automatic or manual measurement
- Battery Power (3 alkaline or Ni-Cd “AA”)
- Date/Time display: 1997-2096 & auto leap year
- Multiple measurement intervals – adapts to patient’s exact requirements
- Data output to computer or printer
- RS-232C Connectivity
Features
| BP Measurement | |
| Measurement Method | Oscillometric |
| Measuring Range | |
| Blood Pressure | 40 ~ 280 mmHg (SYS – 60 ~ 280mmHg/DIA – 40 ~ 160mmHg) |
| Pulse | 30 ~ 200 bpm |
| Accuracy | |
| Blood Pressure | +/- 3 mmHg |
| Pulse | +/-5% |
| Pressurization | |
| Method | Micro pump |
| Maximum Pressure | 300 mmHg |
| Preset Pressure | Automatic |
| Depressurization | |
| Method | Electric Controlled Exhaust Valve (ECEV) |
| Safety System | A magnetic, solenoid valve opens when the pressure exceeds approximately 320 mmHg. Over 330 mmHg, an independent safety circuit exhausts air. |
| Interval Setting | 5, 10, 15, 20, 30, 60, 120 min. |
| Clock | 24 hour clock, calendar (~ year 2096) |
| Memory Data | Up to 300 sets of data |
| Power Supply | |
| Battery | 3x LR6 (“AA”) type batteries – alkaline or Ni-cd type |
| Battery Life | Approx. 200 measurements |
| Temperature & Humidity | |
| Operating Temperatures | 10°C ~ 40°C (50°F ~ 104°F), Less than 85%RH (non-condensing) |
| Storage & Transportation | -20°C ~ 55°C (14°F ~ 131°F), Less than 95%RH (non-condensing) |
| External Dimensions | 72(W) x 27(H) x 100(D) mm/2.8(W) x 1.0(H) x 3.9(D) inches |
| Weight | Approx. 215g (0.47lb) without cuff |