LC-4103 (Aluminum) For use with medium size platforms, single point compact load cells
- Parallelogram-type construction
- 400 × 600 mm platforms can be used
- Temperature compensation maintains both zero and span from -10 °C to +40 °C (+14 °F to +104 °F)
- Deadweight up to 80% of capacity. Load weight and deadweight up to 180% of capacity
- Moisture proof
- Compact and lightweight
Rated capacities ……………………..60 kgf, 100 kgf, 150 kgf
Rated output …………………………….1 mV/V+15/-0%
Maximum deadweight ……………..80% of rated capacity
Maximum safe overload ………….300% of rated capacity
Combined error ………………………±0.015% of rated output
Creep ………………………………………±0.05% of rated output/hour
Zero balance ………………………….20 ± 5% of rated output
Compensated
temperature range …………………-10 °C to +40 °C/+14 °F to +104 °F
Recommended
excitation voltage …………………..12 V
Maximum excitation
voltage …………………………………..15 V
input terminal resistance ………Approximately 400 Ω
Output terminal resistance …..350 Ω ± 5 Ω
Insulation resistance ……………Greater than 5000 MΩ at DC50 V
Temperature effect
Zero ………………………………………0.004% of rated output/°C
Span ……………………………………..0.0014% of rated output/°C Typ.
Platform size ………………………..400 × 600 mm/15.8 × 23.6 inches
Cable length ………………………..2 m/78 inches
Highlights
- Parallelogram-type construction
- 400 × 600 mm platforms can be used
- Temperature compensation maintains both zero and span from -10 °C to +40 °C (+14 °F to +104 °F)
- Deadweight up to 80% of capacity. Load weight and deadweight up to 180% of capacity
- Moisture proof
- Compact and lightweight
Features
Rated capacities ……………………..60 kgf, 100 kgf, 150 kgf
Rated output …………………………….1 mV/V+15/-0%
Maximum deadweight ……………..80% of rated capacity
Maximum safe overload ………….300% of rated capacity
Combined error ………………………±0.015% of rated output
Creep ………………………………………±0.05% of rated output/hour
Zero balance ………………………….20 ± 5% of rated output
Compensated
temperature range …………………-10 °C to +40 °C/+14 °F to +104 °F
Recommended
excitation voltage …………………..12 V
Maximum excitation
voltage …………………………………..15 V
input terminal resistance ………Approximately 400 Ω
Output terminal resistance …..350 Ω ± 5 Ω
Insulation resistance ……………Greater than 5000 MΩ at DC50 V
Temperature effect
Zero ………………………………………0.004% of rated output/°C
Span ……………………………………..0.0014% of rated output/°C Typ.
Platform size ………………………..400 × 600 mm/15.8 × 23.6 inches
Cable length ………………………..2 m/78 inches